EasyManua.ls Logo

Newmac NS220E - User Manual

Newmac NS220E
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTALLATION, OPERATING
and
SERVICE MANUAL
THE INSTALLATION OF THE UNIT SHALL BE IN ACCORDANCE WITH THE
REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION.
HEAD OFFICE
MARKETING / PRODUCTION
Newmac Mfg. Inc.
DEBERT AIR INDUSTRIAL PARK,
208 LANCASTER CRESCENT
P.O. BOX 9, DEBERT
NOVA SCOTIA, BOM 1G0
PHONE: 902-662-3840
FAX: 902-662-2581
WAREHOUSE
Newmac Mfg. Inc.
430 SPRINGBANK AVE., SOUTH
WOODSTOCK, ONTARIO
N4V 1B2
PHONE: 519-539-6147
FAX: 519-539-0048
EMAIL: newmac@newmacfurnaces.com
HOMEPAGE: newmacfurnaces.com
NOTICE TO HOMEOWNER:
READ AND SAVE THESE INSTRUCTIONS
2210243 FEBRUARY 2012
STATUS EPA, CLASSIC I EPA, CLASSIC II EPA WOODSTOVE
MODELS NS220E, NC100E & NCM120E
Printed:Subject to change without notice
156156
Question and Answer IconNeed help?

Do you have a question about the Newmac NS220E and is the answer not in the manual?

Summary

Installation Requirements

Critical Safety Warnings

Essential safety precautions for installation and operation, including warnings against specific actions.

Chimney System Requirements

Specifies approved chimney types, connection standards, and materials for safe venting.

Heater Installation Procedure

Step-by-step guide for physically installing the heater unit, including placement and connections.

Pre-Firing Checks and Clearances

Floor Protection Clearances

Minimum distances required for non-combustible floor protection materials around the heater.

Wall Clearances for NS220 E Model

Safety distances required from combustible walls and ceilings for the NS220E model.

Wall and Ceiling Clearances by Model

Clearances for NC100 E Model

Safety distances required from combustible walls and ceilings for the NC100E model.

Clearances for NCM120 E Model

Safety distances required from combustible walls and ceilings for the NCM120E model.

Reduced Clearance Installation

Wall Protection for Reduced Clearances

Methods and materials for safely reducing clearances using non-combustible wall protection.

Heater Control Operation

Thermostat and Burn Rate Dial Use

Instructions on adjusting the thermostat and burn rate controls for optimal performance.

Safe Installation and Operation Guidelines

Key Cautions and Warnings

Important safety notes and warnings to prevent hazards during installation and use.

Chimney Connector Pipe Details

Specifications and requirements for the stovepipe connector, including material and sealing.

Chimney and Fireplace Connection Methods

Masonry Chimney Connection

Procedures for safely connecting the heater to a masonry chimney.

Masonry Fireplace Connection

Guidelines for connecting the heater to a masonry fireplace, including flue area.

Chimney System Installation Standards

Factory-Built Chimney Connection

How to connect the heater to listed factory-built chimney systems.

Fundamental Chimney Principles

Basic rules for effective and safe chimney operation, including termination heights.

Combustion Air Supply

Outside Air for Combustion

Importance and methods for supplying outside combustion air to ensure proper operation.

Ducting Outside Air

Specifics on routing external air to the heater, including duct size and termination.

Fuel, Air, and Flue Basics

Fuel Selection and Loading

Guidance on appropriate wood fuel types and safe methods for loading the heater.

Combustion Air Systems Explained

Overview of primary and secondary air inlets and their functions for efficient burning.

Secondary Air System Functionality

Secondary Air Timer (SAT) Usage

Detailed instructions for operating the Secondary Air Timer for optimal burn and efficiency.

Monitoring Chimney Smoke Output

Visual cues from the chimney indicating correct heater operation and heat loss.

Heater Startup and Reloading

Lighting Procedure

Step-by-step guide to safely and effectively start the heater.

Refueling Safely

Best practices for adding fuel to a burning heater to maintain draft and prevent back-puffing.

Operation, Troubleshooting, and Ash Handling

Troubleshooting Common Issues

Addresses common problems like smoke, high fuel use, back-draft, and back-puff.

Safe Ash Disposal Procedures

Recommended methods for safely handling, storing, and disposing of ashes.

Assembly and Mobile Home Installation

NS220 E Model Assembly Steps

Instructions for assembling the NS220E unit, including base and firebox attachment.

Mobile Home Installation Requirements

Specific requirements for installing the heater in a mobile home, including anchoring.

Installation Structural Details

Framing and Ceiling Support

Guidance on structural framing dimensions and ceiling support box installation.

Air Intake Duct Location

Placement and dimensions for the outside air intake duct and floor protector.

Air Duct and Chimney Termination

Outside Air Duct Installation Steps

Procedures for connecting the outside air duct to the heater and floor.

Chimney Height and Pitch Rules

Regulations for chimney termination height above the roof and roof pitch considerations.

Chimney Finishing and Maintenance

Roof Flashing Installation Guide

How to properly install roof flashing for a watertight seal around the chimney.

Chimney Removal for Mobile Homes

Instructions for disconnecting and removing the chimney for mobile home transport.

Creosote Management and Safety

Understanding Creosote Causes

Explains why creosote forms and how to minimize its buildup for safety.

Creosote Fire Prevention

Advice on inspection frequency and measures to prevent chimney fires.

Heater Safety, Care, and Repair

Chimney Fire Safety Procedures

Actions to take if a chimney fire is suspected, including reducing air and securing doors.

Enamel Care and Door Adjustment

How to maintain the exterior enamel finish and adjust the loading door seal.

Optional Circulating Fan Installation

Fan Unit Installation and Operation

Instructions for fitting and using the optional circulating fan for improved air distribution.

Parts, Warranty, and Support

How to Order Spare Parts

Information on identifying and ordering replacement components using part numbers.

Warranty Claim Process

Steps required to initiate and process a warranty claim, including required documentation.

NS220 E Replacement Parts

NS220 E Parts List and Numbers

Comprehensive list of part numbers and descriptions for the NS220E model.

NS220 E Parts Diagram

NS220 E Exploded View Diagram

Visual guide showing the location of components for the NS220E model.

NC100 E Replacement Parts

NC100 E Parts List and Numbers

Comprehensive list of part numbers and descriptions for the NC100E model.

NC100 E Parts Diagram

NC100 E Exploded View Diagram

Visual guide showing the location of components for the NC100E model.

NCM120 E Replacement Parts

NCM120 E Parts List and Numbers

Comprehensive list of part numbers and descriptions for the NCM120E model.

NCM120 E Parts Diagram

NCM120 E Exploded View Diagram

Visual guide showing the location of components for the NCM120E model.

EPA Emissions Data - Status EPA

Status EPA Smoke and Efficiency Ratings

EPA performance metrics for smoke emission and efficiency for the Status EPA model.

EPA Emissions Data - Classic I EPA

Classic I EPA Smoke and Efficiency Ratings

EPA performance metrics for smoke emission and efficiency for the Classic I EPA model.

EPA Emissions Data - Classic II EPA

Classic II EPA Smoke and Efficiency Ratings

EPA performance metrics for smoke emission and efficiency for the Classic II EPA model.

Newmac Wood-Stove Limited Warranty

Warranty Terms, Exclusions, and Claims

Detailed explanation of warranty coverage, exclusions, and procedures for making a claim.

Newmac NS220E Specifications

General IconGeneral
Fuel TypeWood
Efficiency75% HHV
Weight450 lbs
EPA certifiedYes
Heating Area1, 200 - 2, 200 sq ft
Emissions2.5 g/hr
Heating capacity1, 200 - 2, 200 sq ft

Related product manuals