EasyManua.ls Logo

NI C Series - Page 16

Default Icon
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NI 9795 User Guide and Specifications 16 ni.com
Figure 6. Same Network Configuration Example
In this configuration, R
1
can still communicate with the gateway,
but R
2
is now connected through R
1
. This means that all
measurements taken by R
2
must hop through R
1
before making it
back to the gateway. In addition, R
1
is now not only responsible for
sending its own measurement data, but also the R
2
data. This
configuration is considered a worst-case 2-hop system, as R
2
and
R
1
both have the possibility of meshing through a router that is
connected to the gateway. National Instruments recommends
configuring your system for no more than three hops. Configuring
multiple nodes as routers and placing them within close proximity
R
1
G
R
2

Other manuals for NI C Series

Related product manuals