Technical specifications
AG-WT10-7AG-WT10-4
Electrical data
230 V ~ 50 HzRated voltage
0.079 kW/0.35 A0.046 kW/0.22 AMax. specified power/operating current
Pipe connections
6.35 mm (1/4")6.35 mm (1/4")Pipe connection (liquid)
12.7 mm (1/2")9.52 mm (3/8")Pipe connection (gas)
0.8 mm0.8 mmMin. thickness refrigerant pipe
Dimensions and weight
14 kg10 kgWeight
970 mm845 mmWidth
300 mm289 mmHeight
224 mm209 mmDepth
Recommended working range
1)
-20/50 °CMin/max outdoor temp. during cooling
10/32 °CMin/max indoor temp. during cooling
-20/24 °CMin/max outdoor temp. during heating
0/27 °CMin/max indoor temp. during heating
Miscellaneous
36/39/42/46 dB(A)25/31/39/42 dB(A)Sound pressure level, fan speed low-high
2)
520-800 m
3
/h330-660 m
3
/hAirflow
2.0 l/h1.5 l/hDehumidification
069134069133Part No.
1)
Access to full capacity is guaranteed within the heat pumps' working
range. Operation outside the recommended working range is possible
as the internal protective functions ensure that the heat pump will not
be damaged.
2)
Sound pressure level measured at 2 m, according to ISO 9614
AG-WT10Chapter 9 | Technical data18