The speed of the fan can be changed depending on the hu-
midity in the air.
The speed of the fan can be changed depending on the
carbon dioxide content in the air.
MENU 7.1.6.4 - LIMIT RH IN HEAT
Here you can activate Humidity control, controlled by the
relative humidity (RH) of the air, during heating operation.
Only shown if a moisture sensor is installed
MENU 7.1.7.2 - HUMIDITY CONTROL
Only shown if a moisture sensor is installed and cooling is
activated.
Prevent condensation in cold
Setting range: on/off
Limit RH in cold
Setting range: on/off
Prevent condensation in cold: With the function activated,
condensation in the pipes is prevented.
Limit RH in cold: With the function activated, the temperature
is regulated to achieve the desired relative humidity (RH).
17CDS 10 | EN