TIP
If you wish to set similar scheduling for every
day of the week start by filling in “all” and then
changing the desired days.
Caution
If the stop time is earlier in the day than the
start time it means that the period extends
past midnight.
Scheduling always starts on the date that the
start time is set for.
If time periods overlap each other at midnight,
the time period that starts after midnight is
prioritised.
Menu 2.9 - advanced
Menu advanced has orange text and is intended for
the advanced user. This menu has a sub-menu.
Menu 2.9.1 - periodic increase
period
Setting range: 1 - 90 days
Factory setting: activated, 14 days
To prevent bacterial growth in the water heater, the
compressor and the immersion heater can increase the
hot water temperature for a short time at regular inter-
vals.
The length of time between increases can be selected
here. The time can be set between 1 and 90 days.
Factory setting is 14 days. Tick/untick "activated" to
start/switch off the function.
27Chapter 8 | Control - MenusNIBE™ F110