3X400 V
F1145-6
400V 3N ~ 50HzRated voltage
13A
rms
Starting current
5.3(16)A
rms
Max operating current including 0 kW immersion heater (Recommended fuse rating).
13(16)A
rms
Max operating current including 1 2 kW immersion heater (Recommended fuse rating).
13(16)A
rms
Max operating current including 3 4 kW immersion heater (Recommended fuse rating).
17(20)A
rms
Max operating current including 5 6 kW immersion heater (Recommended fuse rating).
17(20)A
rms
Max operating current including 7 kW immersion heater, connected on delivery (Recommended fuse rating).
20(20)A
rms
Max operating current including 9 kW immersion heater, requires reconnection (Recommended fuse rating).
1/2/3/4/5/6/7 (switchable to 2/4/6/9)kWAdditional power
30 87WOutput, Brine pump
7 67WOutput, Heating medium pump
IPX1BEnclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
F1145-8
400V 3N ~ 50HzRated voltage
16A
rms
Starting current
6.4(16)A
rms
Max operating current including 0 kW immersion heater (Recommended fuse rating).
14(16)A
rms
Max operating current including 1 2 kW immersion heater (Recommended fuse rating).
14(16)A
rms
Max operating current including 3 4 kW immersion heater (Recommended fuse rating).
18(20)A
rms
Max operating current including 5 6 kW immersion heater (Recommended fuse rating).
18(20)A
rms
Max operating current including 7 kW immersion heater, connected on delivery (Recommended fuse rating).
21(25)A
rms
Max operating current including 9 kW immersion heater, requires reconnection (Recommended fuse rating).
1/2/3/4/5/6/7 (switchable to 2/4/6/9)kWAdditional power
30 87WOutput, Brine pump
7 67WOutput, Heating medium pump
IPX1BEnclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
F1145-10
400V 3N ~ 50HzRated voltage
21A
rms
Starting current
8.3(16)A
rms
Max operating current including 0 kW immersion heater (Recommended fuse rating).
15(16)A
rms
Max operating current including 1 2 kW immersion heater (Recommended fuse rating).
15(16)A
rms
Max operating current including 3 4 kW immersion heater (Recommended fuse rating).
19(20)A
rms
Max operating current including 5 6 kW immersion heater (Recommended fuse rating).
19(20)A
rms
Max operating current including 7 kW immersion heater, connected on delivery (Recommended fuse rating).
22(25)A
rms
Max operating current including 9 kW immersion heater, requires reconnection (Recommended fuse rating).
1/2/3/4/5/6/7 (switchable to 2/4/6/9)kWAdditional power
35 185WOutput, Brine pump
7 67WOutput, Heating medium pump
IPX1BEnclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
F1145-12
400V 3N ~ 50HzRated voltage
29A
rms
Starting current
9(16)A
rms
Max operating current including 0 kW immersion heater (Recommended fuse rating).
18(20)A
rms
Max operating current including 1 2 kW immersion heater (Recommended fuse rating).
18(20)A
rms
Max operating current including 3 4 kW immersion heater (Recommended fuse rating).
18(20)A
rms
Max operating current including 5 6 kW immersion heater (Recommended fuse rating).
23(25)A
rms
Max operating current including 7 kW immersion heater, connected on delivery (Recommended fuse rating).
24(25)A
rms
Max operating current including 9 kW immersion heater, requires reconnection (Recommended fuse rating).
1/2/3/4/5/6/7 (switchable to 2/4/6/9)kWAdditional power
35 185WOutput, Brine pump
7 67WOutput, Heating medium pump
IPX1BEnclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
73Chapter 12 | Technical dataNIBE F1145

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1145 series and is the answer not in the manual?

Nibe F1145 series Specifications

General IconGeneral
BrandNibe
ModelF1145 series
CategoryHeat Pump
LanguageEnglish

Related product manuals