F1145-15
400V 3N ~ 50HzRated voltage
43A
rms
Starting current
11(16)A
rms
Max operating current including 0 kW immersion heater (Recommended fuse rating).
20(20)A
rms
Max operating current including 1 – 2 kW immersion heater (Recommended fuse rating).
20(20)A
rms
Max operating current including 3 – 4 kW immersion heater (Recommended fuse rating).
20(20)A
rms
Max operating current including 5 – 6 kW immersion heater (Recommended fuse rating).
24(25)A
rms
Max operating current including 7 kW immersion heater, connected on delivery (Recommended fuse rating).
26(30)A
rms
Max operating current including 9 kW immersion heater, requires reconnection (Recommended fuse rating).
1/2/3/4/5/6/7 (switchable to 2/4/6/9)kWAdditional power
35 – 185WOutput, Brine pump
10 – 87WOutput, Heating medium pump
IPX1BEnclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
F1145-17
400V 3N ~ 50HzRated voltage
52A
rms
Starting current
13(16)A
rms
Max operating current including 0 kW immersion heater (Recommended fuse rating).
22(25)A
rms
Max operating current including 1 – 2 kW immersion heater (Recommended fuse rating).
22(25)A
rms
Max operating current including 3 – 4 kW immersion heater (Recommended fuse rating).
22(25)A
rms
Max operating current including 5 – 6 kW immersion heater (Recommended fuse rating).
26(30)A
rms
Max operating current including 7 kW immersion heater, connected on delivery (Recommended fuse rating).
28(30)A
rms
Max operating current including 9 kW immersion heater, requires reconnection (Recommended fuse rating).
1/2/3/4/5/6/7 (switchable to 2/4/6/9)kWAdditional power
35 – 185WOutput, Brine pump
10 – 87WOutput, Heating medium pump
IPX1BEnclosure class
Equipment Compliant with IEC 61000-3-12
For Connection Design Purposes, Compliant with IEC 61000-3-3 technical requirements
NIBE F1145Chapter 12 | Technical data74