Caution
If you choose to switch off hot water production during the vacation
“periodic increases" (preventing bacterial growth) are blocked during this
time. "periodic increases" started in conjunction with the vacation setting
being completed.
advanced
DGYDQFHG
RS SULRULWLVDWLRQ
DXWR PRGH VHWWLQJ
GHJUHH PLQXWH VHWWLQJ
IDFWRU\ VHWWLQJ XVHU
VFKHGXOH EORFNLQJ
RII
Menu advanced has orange text and
is intended for the advanced user. This
menu has several sub-menus.
Menu
4.9
op. prioritisation
RS SULRULWLVDWLRQ
PLQ
PLQ
PLQ
KRW ZDWHU
KHDWLQJ
SRRO
op. prioritisation
Setting range: 0 to 180 min
Default value: 30 min
Choose here how long the heat pump should work with each requirement
if there are two or more requirements at the same time. If there is only
one requirement the heat pump only works with that requirement.
The indicator marks where in the cycle the heat pump is.
If 0 minutes is selected it means that requirement is not prioritised, but
will only be activated when there is no other requirement.
Menu
4.9.1
57NIBE™ F1145Chapter 3 | F1145 – at your service