Electrical data
1X230V
F1155-6
Electrical data
230V ~ 50HzRated voltage
15(16)A
rms
Max operating current including 0 0.5 kW immersion heater (Recommended fuse rating).
20(20)A
rms
Max operating current including 1 1.5 kW immersion heater (Recommended fuse rating).
24(25)A
rms
Max operating current including 2 2.5 kW immersion heater (Recommended fuse rating).
31(32)A
rms
Max operating current including 3 4 kW immersion heater (Recommended fuse rating).
33(40)A
rms
Max operating current including 4.5 kW immersion heater (Recommended fuse rating).
0.5/1/1.5/2/2.5/3
/3.5/4/4.5
kWAdditional power
F1155-12
Electrical data
230 V ~ 50 HzRated voltage
26(32)A
rms
Max operating current including 0 1 kW immersion heater (Recommended fuse rating).
39(40)A
rms
Max operating current including 2 4 kW immersion heater (Recommended fuse rating).
52(63)A
rms
Max operating current including 5 7 kW immersion heater (Recommended fuse rating).
1/2/3/4/5/6/7kWAdditional power
NIBE F1155Chapter 12 | Technical data68

Other manuals for Nibe F1155 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1155 Series and is the answer not in the manual?

Nibe F1155 Series Specifications

General IconGeneral
RefrigerantR410A
Control SystemNIBE SMO 40
InstallationIndoor
Heating Capacity1.5-16 kW
Cooling CapacityNot applicable
Power Input CoolingNot applicable
EER CoolingNot applicable
Weight Outdoor UnitNot applicable
Dimensions Outdoor Unit (HxWxD)Not applicable
Dimensions Indoor Unit (HxWxD)600 x 620 mm

Related product manuals