Menu 5 - SERVICE
OVERVIEW
5.1.1 - hot water settings *5.1 - operating settings **5 - SERVICE **
5.1.2 - max flow line temperature
5.1.3 - max diff flow line temp.
5.1.4 - alarm actions
5.1.5 - fan sp. exhaust air *
5.1.7 - br pmp al set.
5.1.8 - operating mode brine pump
**
5.1.9 - brine pump speed **
5.1.10 - op. mod heat med pump **
5.1.11 - pump speed heating medium
**
5.1.12 - internal electrical addition
5.1.14 - flow set. climate system
5.1.22 - heat pump testing
5.1.24 - blockFreq
5.2.1 - master/slave mode **5.2 - system settings
5.2.2 - installed slaves
5.2.3 - docking
5.2.4 - accessories
5.3.1 - FLM *5.3 - accessory settings
5.3.2 - shunt controlled add. heat *
5.3.4 - solar heating *
5.3.6 - step controlled add. heat
5.3.8 - hot water comfort *
5.3.11 - modbus *
5.3.12 - exhaust/supply air module *
5.3.15 - GBM communications mod-
ule *
5.3.16 - humidity sensor *
5.3.21 - flow sensor / energy meter*
5.4 - soft in/outputs **
5.5 - factory setting service **
5.6 - forced control **
5.7 - start guide **
5.8 - quick start **
5.9 - floor drying function
5.10 - change log **
* Accessory needed.
** This menu is also set in the slave heat pump's limited
menu system.
Go to the main menu and hold the Back button in for 7
seconds to access the Service menu.
Sub-menus
Menu SERVICE has orange text and is intended for the
advanced user. This menu has several sub-menus.
Status information for the relevant menu can be found
on the display to the right of the menus.
operating settings Operating settings for the heat
pump.
system settings System settings for the heat pump,
activating accessories etc.
accessory settings Operational settings for different
accessories.
soft in/outputs Setting software controlled in and out-
puts on the input circuit board (AA3).
factory setting service Total reset of all settings (includ-
ing settings available to the user ) to default values.
forced control Forced control of the different compon-
ents in the heat pump.
start guide Manual start of the start guide which is run
the first time the heat pump is started.
quick start Quick starting the compressor.
43Chapter 8 | Control - MenusNIBE F1155

Other manuals for Nibe F1155 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1155 Series and is the answer not in the manual?

Nibe F1155 Series Specifications

General IconGeneral
RefrigerantR410A
Control SystemNIBE SMO 40
InstallationIndoor
Heating Capacity1.5-16 kW
Cooling CapacityNot applicable
Power Input CoolingNot applicable
EER CoolingNot applicable
Weight Outdoor UnitNot applicable
Dimensions Outdoor Unit (HxWxD)Not applicable
Dimensions Indoor Unit (HxWxD)600 x 620 mm

Related product manuals