F1245-8Model
Air-water
Exhaust-water
Brine-water
Water-water
Type of heat pump
Yes No
Low-temperature heat pump
Yes No
Integrated immersion heater for additional heat
Yes No
Heat pump combination heater
Average Cold Warm
Climate
Average (55 °C) Low (35 °C)
Temperature application
EN-14825, EN-16147 & EN12102Applied standards
%147ƞ
s
Seasonal space heating energy efficiencykW9,20PratedRated heat output
Declared coefficient of performance for space heating at part load and at outdoor
temperature Tj
Declared capacity for space heating at part load and at outdoor temperature Tj
-3.31COPdTj = -7 °CkW7.4PdhTj = -7 °C
-3.93COPdTj = +2 °CkW7.7PdhTj = +2 °C
-4.30COPdTj = +7 °CkW7.9PdhTj = +7 °C
-4.73COPdTj = +12 °CkW8.0PdhTj = +12 °C
-3.49COPdTj = bivkW7.5PdhTj = biv
-3.09COPdTj = TOLkW7.2PdhTj = TOL
-COPdTj = -15 °C (if TOL < -20 °C)kWPdhTj = -15 °C (if TOL < -20 °C)
°C-10TOLMin. outdoor air temperature°C-5T
biv
Bivalent temperature
-COPcycCycling interval efficiencykWPcychCycling interval capacity
°C65WTOLMax supply temperature-1.00CdhDegradation coefficient
Additional heatPower consumption in modes other than active mode
kW2.0PsupRated heat outputkW0.002P
OFF
Off mode
kW0P
TO
Thermostat-off mode
ElectricType of energy inputkW0.007P
SB
Standby mode
kW0.014P
CK
Crankcase heater mode
Other items
m
3
/hRated airflow (air-water)FixedCapacity control
m
3
/h0.79Nominal heating medium flowdB42 / -L
WA
Sound power level, indoors/outdoors
m
3
/h1.43Brine flow brine-water or water-water heat pumpskWh4,907Q
HE
Annual energy consumption
For heat pump combination heater
%100ƞ
wh
Water heating energy efficiencyXLDeclared load profile for water heating
kWhQ
fuel
Daily fuel consumptionkWh7.60Q
elec
Daily energy consumption
GJAFCAnnual fuel consumptionkWh1,669AECAnnual energy consumption
NIBE Energy Systems Box 14 Hannabadsvägen 5 285 21 Markaryd SwedenContact information
77Chapter 12 | Technical dataNIBE F1245

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1245 Series and is the answer not in the manual?

Nibe F1245 Series Specifications

General IconGeneral
BrandNibe
ModelF1245 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals