Important information
NOTE
This symbol indicates danger to person or ma-
chine .
Caution
This symbol indicates important information
about what you should observe when maintain-
ing your installation.
General
POOL 40 is an accessory that enables pool heating in
your climate unit.
A reversing valve (QN19) can be connected to direct part,
or all, of the heating medium supply to a pool exchanger.
The reversing valve, or, if required the reversing valves
(however, with the same control signal), is/are installed
on the heating medium circuit that goes to the radiator
system as normal. In systems with a cascade connection
you determine in the control system how many com-
pressors are permitted to work with pool heating. Extern-
al circulation pump (GP10) to the climate system must
be installed if one or more pools is docked to the system.
During pool heating the heating medium is circulated
between the heat pump and the pool exchanger using
the heat pump's internal circulation pumps. An external
circulation pump (GP9) circulates the heating medium
between the pool exchanger and the pool.
The external circulation pump (GP10) circulates the
heating medium water in the climate systems, and the
additional heat can be engaged as necessary, at the same
time as the external supply temperature sensor continu-
ally meters the heating demand of the house.
The heat pump controls the reversing valve (QN19), pool
circulation pump (GP9) and any heating circuit circulation
pumps (GP10) via POOL 40.
Up to two different pool systems can be connected to
the F1345/F1355 or SMO 40 and be controlled individu-
ally, although this requires two POOL 40 accessories.
Compatible products
F1345
F1355
SMO 40
F1145
F1155
F1245
F1255
Contents
Actuator reversing valve1 x
Shuttle valve1 x
Kit for accessory card1 x
Heating pipe paste2 x
Aluminium tape1 x
Insulation tape1 x
Temperature sensor2 x
Cable ties4 x
Component location unit box (AA25)
LEK
AA5-X4
AA5-S2
AA5-X2 AA5-X9 X1
FA1
AA5-F1AA5
Electrical components
Miniature circuit breaker, 10 AFA1
Terminal block, power supplyX1
Accessory cardAA5
Terminal block, sensors and external block-
ing
AA5-X2
Terminal block, communicationAA5-X4
Terminal block, circulation pumps and re-
versing valve
AA5-X9
Terminal block, reversing valveAA5-X10
DIP switchAA5-S2
Fine wire fuse, T4AH250VAA5-F1
Designations in component locations according to
standard IEC 81346.
13POOL 40 | GB