Connection of the circulation pump, pool
circuit (GP9)
Connect the circulation pump (GP9) to AA5-X9:8 (230
V), AA5-X9:7 (N) and X1:3 (PE).
1
2
3
4
5
6
7
8
9
L
N
PE
3
2
1
1
2
3
4
5
6
7
8
9
3
2
1
Unit box
External
GP9
AA5-X9
X1
Connection of the circulation pump, climate
system (GP10)
If the climate system does not already have an external
pump, one can be connected to the accessory card.
Connect the circulation pump (GP10) to AA5-X9:2 (230
V), AA5-X9:1 (N) and X1:3 (PE).
1
2
3
4
L
N
PE
3
2
1
Unit box
External
AA5-X9
GP10
X1
Connection of the reversing valve motor
(QN19)
Connect the motor (QN19) to AA5-X9:6 (signal), AA5-
X9:5 (N) and AA5-X10:2 (230 V).
-X10
1
2
3
4
5
6
7
8
9
Black
Blue
Brown
-X10
1
2
3
4
5
6
7
8
9
2
Unit box External
AA5-X9
QN19
AA5-X10
1
DIP switch
The DIP switch on the accessory card must be set as fol-
lows.
ON
1 2 3 4 5 6 7 8
-X9
-X2
24 20212223 1516171819 1011121314 56789 1
1
N
L
PE
PE
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
9
234
-X8
-X4
-X10
-X1
AA5-S2
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Pool 1 Pool 2
21POOL 40 | GB