EMERGENCY MODE
Emergency mode is used in event of operational interference
and in conjunction with service.
When S1156 is put into emergency mode, the system works
as follows:
The compressor is blocked.
S1156 prioritises heating production.
Hot water is produced if possible.
Max output for the immersion heater in emergency mode,
limited according to the setting in menu 7.1.8.2 - "Emer-
gency mode".
Fixed supply temperature if the system has no value from
the outdoor temperature sensor (BT1).
When the emergency mode is active, the status lamp is yel-
low.
You can activate the emergency mode both when S1156 is
running and when it is switched off.
To activate when S1156 is running: press and hold the on/off
button (SF1) for 2 seconds and select "emergency mode"
from the shutdown menu.
To activate emergency mode when S1156 is switched off:
press and hold the on/off button (SF1) for 5 seconds. (De-
activate the emergency mode by pressing once.)