1.
Close the shut-off valves (QM31), (QM32), (QM33)
and (QM34).
Drain the compressor module according to the in-
structions on page 59
2.
Pull off the lock catches.
3.
Disconnect the pipe connection under the shut-off
valve (QM31).
4.
Remove the two screws.
5.
Disconnect the connectors (XF2), (XF11) and (XF22).
6.
Carefully pull out the cooling module.
TIP
The cooling module is installed in reverse order.
NOTE
During reassembly, the enclosed O-rings
should replace the existing ones on the shut-
off valves (QM32), (QM33) and (QM34).
61Chapter 10 | ServiceNIBE S1255