EasyManua.ls Logo

Nibe SMO S40 - Page 14

Nibe SMO S40
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Low hot water temperature or a lack of hot
water
This part of the fault-tracing chapter only applies if the
water heater is installed in the system.
Closed or choked filling valve for the hot water.
Open the valve.
Mixing valve (if there is one installed) set too low.
Adjust the mixer valve.
SMO S40 in incorrect operating mode.
Contact your installer!
Large hot water consumption.
Wait until the hot water has heated up. Temporarily
increased hot water capacity can be activated in
home screen "hot water" or in menu 2.1.
Too low hot water setting.
Enter menu 2.2 and select a higher demand mode.
Low hot water access with the “Smart Control”
function active.
If the hot water usage has been low for an extended
period of time, less hot water than normal will be
produced. Activate "More hot water" in menu 2.1.
Too low or no operating prioritisation of hot water.
Contact your installer!
"Holiday" activated in menu 6.1.
Enter menu 6.1 and deactivate.
Low room temperature
Closed thermostats in several rooms.
Set the thermostats to max in as many rooms as
possible. Adjust the room temperature via home
screen heating, rather than choking the thermostats.
SMO S40 in incorrect operating mode.
Contact your installer!
Too low set value on the automatic heating control.
Go to the Smartguide for help in increasing heating.
You can also change the heating from the home
screen heating.
Too low or no operating prioritisation of heat.
Contact your installer!
"Holiday mode" activated in menu 6.1.
Enter menu 6.1 and deactivate.
External switch for changing room temperature activ-
ated.
Check any external switches.
Air in the climate system.
Vent the climate system.
Closed valves to the climate system.
Closed valves to the climate system or heat pump.
Open the valves (contact your installer for assistance
in finding them).
High room temperature
Too high set value on the automatic heating control.
Go to the Smartguide for help in decreasing heating.
You can also change the heating from the home
screen heating.
External switch for changing room temperature activ-
ated.
Check any external switches.
Low system pressure
Not enough water in the climate system.
Fill the climate system with water and check for
leaks. In event of repeated filling, contact the in-
staller.
The air/water heat pump’s compressor does
not start
There is no heating or cooling demand, nor hot water
demand or pool demand.
SMO S40 does not call on heating, cooling, hot wa-
ter or pool.
Compressor blocked due to the temperature condi-
tions.
Wait until the temperature is within the product’s
working range.
Minimum time between compressor starts has not
been reached.
Wait for at least 30 minutes and then check if the
compressor has started.
Alarm tripped.
Follow the display instructions.
NIBE SMO S40Chapter 6 | Disturbances in comfort14