15VEDEX 3300
Other information
Service
Open the combustion chamber door (68).
Pull out the flame trough.
Empty the trough and clean the ash out. Take care to
remove any coked ash residue in the trough.
Clean the chamber.
Position the trough and close the door.
Fan
The fan is a central part of VEDEX 3300 and should be
treated with care. The fan should be removed and cleaned
about twice a year for optimum function and a long ser-
vice life.
Check that the boiler is off and that no embers are in
the combustion chamber.
Disconnect the fan from the electrical socket on the
boiler.
Remove the long nuts securing the fan to the boiler.
Clean the fan blades carefully to prevent deforming
them.
Reinstall the fan and connect the electrical cable.
Sweeping description
Remove the cover from the top of the boiler.
Lift out the turbulators from the convection part.
Sweep the convection part.
Reinstall the turbulators.
Reinstall the soot door.
Service
LEK
13 4
56
2
LEK
E
E