Technical specifications
VPB 1000VPB 750VPB 500Model
950850750mmDiameter
202019251690mmHeight (excl. feet)
280220190kgNet weight
2x91x9kWMax. output
10/1,0bar/MPaMax pressure, water heater
10/1,0bar/MPaMax pressure, coil
95°CMax. operating temperature
2x676litreVolume, coil
2x15,718,815,7mLength, coil
2x5,27,65,2m²Heating surface, coil
31,620,215,8kWHeat transfer, primary 60/50 °C, 50 °C HW temp at the top
956047kWHeat transfer, primary 80/60 °C, 50 °C HW temp at the top
463523kWhHeat content at 50°C
1180890590litreEquivalent amount of hot water (40 °C)*
190150190min.Heating time 10 - 60 °C, VPB 500 1 x 9 kW, VPB 750 and
VPB 1000 2 x 9 kW
CopperCorrosion protection
083 240083 231083 220Part No.
* At incoming temperatures 10 °C and hot water draining of 24 l/min.
Energy labelling
NIBESupplier
VPB 1000 CUVPB 750-2VPB 500 CUModel
FED
Energy efficiency class
254186135WHeat loss
992747496lVolume
Accessories
Not all accessories are available on all markets.
Immersion heater IU
Immersion heater IU 31 - IU 311
See table
Connection box K11
Connection box with thermostat and overheating protec-
tion. (When connecting Immersion heater IU)
Part no. 018 893