41NIBE VVM 300
Miscellaneous
Menu 9.1.9 Stop Temp.(18)*
Stop temperature, set outdoor air temperature when the
downtime relay in the heat pump is activated, and it stops.
Menu 9.1.10 Time bet. starts(19)*
Minimum time interval in minutes between compressor
starts in the heat pump.
Menu 9.1.14 Heat pump stop XHW
The temperature at which extra hot water switches from
compressor operation to immersion heater for hot water is
set here. The same value as in menu 1.2 should be select-
ed.
The value can be set between 45 and 65 °C. The factory
setting is 50 °C.
Menu 9.1.15 Max heat p. time XHW
If the compressor does not manage to obtain the tempera-
ture after this time, SMO 10 switches to combined mode
and the immersion heater starts in the hot water heater.
The value is adjustable between 0 and 20 minutes. The fac-
tory setting is 10 minutes.
Menu 9.1.16 Return
Return to menu 9.1.0.
Settings regarding additional heat and shunt in VVM 300
and any extra shunt can be made on the sub-menus in this
menu.
Menu 9.2.1 Start add. heat.
The degree minute deficit that must be set before the ad-
ditional heat supply is activated is set here.
A value between -1000 and -30 can be set . The factory
setting is -400.
Menu 9.2.2 Time factor
The time factor of the immersion heater since first start
up is shown here. The value is saved and is not reset even
when the boiler is switched off using the main power
switch.
Menu 9.2.6 Shunt amplification
Applies to shunt 1 (43). E.g. 2 degrees difference and 2 in
amplification gives 4 sec/min controlling the shunt.
The value can be set between 1 and 10. The factory setting
is 4.
Menu 9.2.7 Shunt amplification2
Applies to any shunt 2 (SV2) (accessory required). E.g. 2
degrees difference and 2 in amplification gives 4 sec/min
controlling the shunt. This function compensates for the
speed variation found on different shunt motors that may
be installed.
The value can be set between 1 and 10. The factory setting
is 4.
Menu 9.2.8 Return
Return to menu 9.2.0.