Main components
Replacement of immersion heater
1 Set the switch (SF1) to
stand by mode and wait ap-
prox. 30 secs
2 Turn off the power supply
to the heat pump.
3 Close the shut-off valves to
the heating system and heat
pump.
QM20
Drain valve (QM1)
4 Drain the water by open-
ing the drain valve (QM1)
and allow air to enter via the
vents (QM20) until the level
is below the reversing valve
(QN10).