Motor power supply | 24 V DC |
---|---|
Standby consumption | 5 W |
Operating temperature | -20°C to +50°C |
Protection level | IP44 |
Maximum Gate Weight | 500 kg |
Maximum Gate Width | 5 m |
Power supply | 230 V AC (±10%) 50 Hz |
Safety Features | Obstacle detection |
Opening Speed | 0.3 m/s |
Closing Speed | 0.3 m/s |
Covers verification, technical specs, and installation steps for gate automation.
Check gate structure, environment compliance, and mechanical suitability for automation.
Verify compatibility with intended use and observe all manual limitations and warnings.
Details gearmotor and control unit technical specifications, including voltage, power, and dimensions.
Defines installation position of devices, tool requirements, and cable laying.
Instructions for installing gearmotors and the control unit, including safety precautions.
Guidance on positioning and installing photocells for gate automation.
Instructions for installing the flashing light for visual indication.
Details connecting kit devices and other accessories to the control unit terminals.
Instructions for connecting the power supply for operational and programming tests.
Overview of control unit programming keys (P1-P4) and their functions.
Basic checks to perform after powering up the control unit.
Procedure for making the control unit recognize connected devices on ECSbus and Stop terminals.
Explains how to use the selector to specify the motor type connected to the control unit.
Procedure to make the control unit recognize the opening and closing angles of the gate leaves.
Procedure to memorize the first transmitter for controlling the automation.
Covers selection of manoeuvre speed and operating cycle for gate leaves.
Steps to test the gate's opening/closing movements and safety devices.
Procedures for final commissioning after successful testing.
Specifies that maintenance must be performed by qualified personnel and checks should be periodic.
Information on proper disposal of the product and its components according to local regulations.
Details on adjusting control unit operating parameters using the transmitter.
Procedure to add or remove devices from the system and re-run recognition.
Procedures for memorizing transmitters in different modes.
How to cancel individual transmitters or their keys from the control unit's memory.
Procedure to cancel all memorized transmitters from the control unit.
Instructions for installing the back-up battery for emergency power supply.
Guidance on connecting the solar power supply system to the control unit.
Explains LED signals on photocells, flashing lights, and control units for status and anomalies.
Details on ECSbus system, Stop input, and product durability.
Provides probable causes and solutions for common installation and operational faults.
General warnings and safety precautions for gate automation operation and maintenance.
Procedure for manually releasing and locking the gearmotor in case of power outage or fault.
Steps for performing regular maintenance checks on the automation system.
Instructions for replacing the battery in the transmitter.