FUNCTION Button / Adv. Settings (Cont.)
FUNCTION>ADVANCE SETTINGS MENU (Cont.):
’ UL INPUT: For analog, select both, open, or close. For digial, select NC (normally closed) or NO (normally open).
’ SELECT PRIMARY / SECONDARY: Motor1 or Motor2
’ ACTIVATE LINK FOR REMOTE PRIMARY/SECONDARY: Enables control of an additional gate operator board.
’ POWER FAIL OPEN: Opens gate automatically on battery backup power if main AC power input loss is detected.
’ MOTOR 12V: Forces motor control voltage to +12VDC even if the supply voltage varies +9.5VDC up to +35VDC)
’ SET VIRTUAL ENCODER: For motors without built-in encoders.
Both
Open
Close
10. Default (see next page)
NOTICE
When set to 10K RES OPEN, CLOSE, or 10K RES BOTH, input must have an 8.2k-10k Ohm terminated
external entrapment sensor installed. 10K RES BOTH only available for Swing Gates.