18 – English
7.6.3 - Level 2 functions (adjustable parameters)
Table 12 - Functions of the programming upon start-up procedure
LED
Function
Level Value Description
L1 High
When the variable sensitivity is enabled, it can be
set to 3 different activation thresholds. The “High”
variable sensitivity is most suited to small-size
correctly balanced doors.
L1 Variable sensitivity L2 Medium
L3 Low
L1 No recovery
Adjusts the belt/chain recovery value. Once the
door has closed completely, a brief opening ma-
noeuvre is then performed which can be adjusted
using this parameter.
L2 Belt/chain recovery L2 Minimum recovery
L3 Maximum recovery
L1 Short
Controls how long closure slowdown takes.L3 Closure slowdown L2 Average
L3 Long
Note: “ ” default function
Table 13 - Functions of the standard programming mode
LED
Function
Level Value Description
L1 Low
Adjusts the maximum force generated by the
motor to move the door.
L1 Motor force L2 Medium
L3 High
L1 Open - Stop - Close - Open
Adjusts the sequence of commands associated
with the “Step-by-step” input or the 1st radio
command (see tables 8 and 9).
L2 SbS function L2 Open - Stop - Close - Stop
L3 Condominium
L1 15 seconds
Adjusts the pause time, that is, the time that
elapses before automatic re-closure. Is effective
only if automatic closure is enabled
L3 Pause Time L2 30 seconds
L3 60 seconds
Note: “ ” default function
All the parameters can be adjusted as required without any contraindications; only the adjustment of “motor force” could require special attention:
• Do not use high force values to compensate for points of abnormal friction on the leaf. Excessive force can compromise the operation of the
safety system or damage the leaf. • If the “motor force” control is used to assist the impact force reduction system, measure the force again after
each adjustment in compliance with the EN 12445 standard. • Wear and atmospheric conditions inuence the door’s movement, so the force
settings should be checked periodically.
7.6.4 - Level 2 programming (adjustable parameters)
Table 14 - Programming on start-up procedure
01. Disconnect the power supply to SPIN
02. Hold down the Set key until step 04