17
Selecng a safety level. Overload Seng
From Standby status
- “Selected” mode -
- Standby
This adjusts the force level, over and above the nominal
barrier resistance, needed to trigger the safety overload
rounes. Level 1 being the most sensive and 8 being the
least sensive. The factory default is level 3.
Acon
Response
Descripon Display Buzzer Barrier
To enter the program menu.
Press and hold the buon
unl buzzer beeps.
Display and buzzer
conrms.
Programming menu
<or> for opons
Scroll < or > to select the
runme setup opon.
Display scrolls
through opons.
Overload Seng
< = change >
With “Overload Seng” on
the display, press and release
.
Display shows current
opon status.
Overload Seng
< >
Scroll < or > to the required
seng.
Display changes
respecvely.
Overload Seng
< >
With required seng
displayed, press and release
.
Display briey shows
the new seng is
saved.
Overload Seng
Saved = 2
Aer display conrms new
seng.
Overload Seng
< = change >
Display returns to
programming menu
opons list.
Overload Seng
< = change >
x2
x1
x1
Scroll le or right to next
program opon.
OR
“Selected” mode
- Standby
EXIT back to standby
status
x2
Safety infra-red beams setup. Beam Setup.
From Standby status
- “Selected” mode -
- Standby
Use this opon to enable the safety beam circuit for use in
standard BT mode. (See page 20)
Acon
Response
Descripon Display Buzzer Barrier
To enter the program menu.
Press and hold the buon
unl buzzer beeps.
Display and buzzer
conrms.
Programming menu
<or> for opons
Scroll < or > to select the
beam setup opon.
Display scrolls
through opons.
Beam Setup
< = change >
With “Beam Setup” on the
display, press and release .
Display shows current
opon status.
Beam Setup
Disabled
Scroll < or > to toggle
between “Enabled” and
“Disabled”.
Display changes
respecvely.
Beam Setup
Enabled
With required seng
displayed, press and release
.
Display briey shows
the new seng is
saved.
Beam Setup
Enabled Saved
Aer display conrms new
seng.
Beam Setup
Enabled Saved
Display returns to
programming menu
opons list.
Beam Setup
< = change >
x2
x1
x1
Scroll le or right to next
program opon.
OR
“Selected” mode
- Standby
EXIT back to standby
status
x2