17
Selecng a safety level. Overload Seng
From Standby status
- “Selected” mode -
- Standby
This adjusts the force level, over and above the nominal
barrier resistance, needed to trigger the safety overload
rounes. Level 1 being the most sensive and 8 being the
least sensive. The factory default is level 3.
Acon
Response
Descripon Display Buzzer Barrier
To enter the program menu.
Press and hold the buon
unl buzzer beeps.
Display and buzzer
conrms.
Programming menu
<or> for opons
Scroll < or > to select the
runme setup opon.
Display scrolls
through opons.
Overload Seng
< = change >
With “Overload Seng” on
the display, press and release
.
Display shows current
opon status.
Overload Seng
< >
Scroll < or > to the required
seng.
Display changes
respecvely.
Overload Seng
< >
With required seng
displayed, press and release
.
Display briey shows
the new seng is
saved.
Overload Seng
Saved = 2
Aer display conrms new
seng.
Overload Seng
< = change >
Display returns to
programming menu
opons list.
Overload Seng
< = change >
x2
x1
x1
Scroll le or right to next
program opon.
OR
“Selected” mode
- Standby
EXIT back to standby
status
x2
Safety infra-red beams setup. Beam Setup.
From Standby status
- “Selected” mode -
- Standby
Use this opon to enable the safety beam circuit for use in
standard BT mode. (See page 20)
Acon
Response
Descripon Display Buzzer Barrier
To enter the program menu.
Press and hold the buon
unl buzzer beeps.
Display and buzzer
conrms.
Programming menu
<or> for opons
Scroll < or > to select the
beam setup opon.
Display scrolls
through opons.
Beam Setup
< = change >
With “Beam Setup” on the
display, press and release .
Display shows current
opon status.
Beam Setup
Disabled
Scroll < or > to toggle
between “Enabled” and
“Disabled”.
Display changes
respecvely.
Beam Setup
Enabled
With required seng
displayed, press and release
.
Display briey shows
the new seng is
saved.
Beam Setup
Enabled Saved
Aer display conrms new
seng.
Beam Setup
Enabled Saved
Display returns to
programming menu
opons list.
Beam Setup
< = change >
x2
x1
x1
Scroll le or right to next
program opon.
OR
“Selected” mode
- Standby
EXIT back to standby
status