5.10.2 Menu 0 - Ethernet set-up (MM.ppp)
Table 5-5 Menu 0 parameters
Menu 0 within the SI-Ethernet option module, is also displayed in the drive menu 15, 16 or 17
depending on which slot the option module is installed to and the setting of the Option Slot
Identifiers parameter (S.11.056).
By default, the SI-Ethernet option module will be either menu 15, 16 or 17 and the onboard
Ethernet interface will be menu 24.
Table 5-6 Menu 0 slot availability details the drive models and their available slots and associated
drive menus for use with both the SI-Ethernet option module and the onboard Ethernet interface.
Table 5-6 Menu 0 slot availability
Parameter Range Default Access
Size
(Bits)
S.00.000 Parameter mm.000 0 to 65535 RW 16
S.00.001 Module ID 0 to 65535
RO 16
S.00.002 Software Version
00.00.00.00 to
99.99.99.99
RO 32
S.00.003 Hardware Version 0.00 to 99.99
RO 16
S.00.004 Serial Number LS 0 to 99999999
RO 32
S.00.005 Serial Number MS 0 to 99999999
RO 32
S.00.006 Status -2 to 3
RO 8
S.00.007 Reset 0 (Off) to 1 (On) 0 (Off) RW 1
S.00.008 Default 0 (Off) to 1 (On) 0 (Off) RW 1
S.00.009 Active Alarm Bits
0000000000000000 to
1111111111111111
0000000000000000 RO 16
S.00.010 Active IP Address
0.0.0.0 to
255.255.255.255
0.0.0.0 RO 32
S.00.011 Reserved
S.00.054 Reserved
Drive model Module Slot number Drive menu (MM)
M200 / M201 / M300 / M400
SI-Ethernet
115
2 N/A
3 N/A
Onboard Ethernet 4 N/A
M600
SI-Ethernet
115
216
317
Onboard Ethernet 4 N/A
M700 / M702
SI-Ethernet
115
216
317
Onboard Ethernet 4 24
M701
SI-Ethernet
115
216
317
Onboard Ethernet 4 N/A