4 Applications
96 Total Station DTM-302 Series Instruction Manual
Outputting data to the COM port 41.2
If you press [ENT] while the [COM] icon is displayed
in an observation screen, a line of data is output to
the COM port.
Note – If
[COM] is displayed, data is not stored to the job when you press [ENT].
The format of the output data is defined by the
setting of the Ext.Comm field in
MENU >
Settings > Comm
. For more information, see
Communications, page 130.
Sample output records through COM port
When the Ext.Comm field is set to NIKON:
TR PN: PT8 SD:000066626 HA:003856010 VA:008048500 HT:0000061757
(TR PN: point name SD HA VA HT; when ACK is returned, PN is incremented.)
When the Ext.Comm field is set to SET:
0006662 0804806 0394324 97
(SD VA HA Chk-SUM)
To output data on the COM port when you press
[ENT], set the Data Rec field in MENU >
Settings > Rec
to COM. For more
information, see Recording, page 131.