Fan
UserSuperuser
Room temperature - Desired room temperature
It is possible to set the desired air intake temperature for the ventilation system.
The desired room temperature is set in the Temperature menu:
• Air (°C) The temperature can be set between 5 and 50°C
(Recommendation: 22°C).
Room temperature - Air intake temperature
It is possible to set the minimum and maximum temperatures of the supply air.
Minimum and maximum temperatures are set in the Temperature menu:
• CP/Minimum winter T7 (°C) States the lowest permitted air intake temperature when the system is operat-
ing in winter mode
(factory setting: 16°C).
• CP/Minimum summer T7 (°C) States the lowest permitted air intake temperature when the system is operat-
ing in summer mode
(factory setting: 5°C).
• CP/Maximum T7 (°C) Enter the desired maximum air intake temperature
(factory setting: 50°C).