Domestic hot water
UserSuperuserInstaller
Temperature - Domestic hot water
You can set the desired domestic hot water temperature.
The temperature of the hot water is set in the temperature:
• CP/Hot water (°C) You can set the desired domestic hot water temperature.
Adjustable between 10 and 65°C
(factory setting: 45°C).
Temperature - Electrical supplementary Domestic hot water
The electrical supplementary of 1.5 kW ensures hot water during periods when the heat pump cannot deliver
enough energy.
Electrical supplementary is set in the Settings menu:
• CP/SHW settings/SHW heater enable Switch electrical supplementary domestic hot water ON or OFF
On: electrical supplementary is enabled
Off: electrical supplementary is disabled
(factory setting: OFF)
Temperature - Min./max temperature Domestic hot water
Min./max temperature for the Domestic hot water is set in the Settings menu:
• CP/SHW settings/SHW minimum temp. (°C) If the temperature in the hot water tank falls below this temperature,
electrical supplementary will start
(factory setting: 36°C).
CP/Hot water/SHW max. temp. (°C) This temperature setting ensures that the compressor is not at
high pressure when no more hot water is needed.
(factory setting: 60°C)
Read Min. /Max temperature of the hot water in the Temperature menu:
• CP/T11 (°C) The temperature sensor in the hot water tank top.
• CP/T12 (°C) The temperature sensor in the hot water tank base.