15
Installation
Assembly
Transport into the dwelling
Compact P is supplied in one piece on a pallet, packed in cardboard.
You can use Nilan lifting trolley, with which the unit can be lifted directly off the pallet and into the building. If the filter box is removed,
the unit can be manoeuvred through an ordinary door.
Positioning of unit
The unit should be positioned on a level and vibration-free substrate, with good access for servicing and filter change.
The unit is fitted at the factory with 4 lifting straps, one for each top corner.
This makes it possible to lift in the unit with a crane, which is a great advantage if the terrain does
not allow you to drive with a lift truck.
When lifting the units with the supplied straps, these must be at an angle of max. 45°from the
vertical.
ATTENTION
When setting up the unit, consideration must always be given to future servicing and maintenance, therefore a free
space in front of the unit of at least 60 cm is recommended.
ATTENTION
To achieve a proper run-off from the condensate tray, it is important that the unit is installed in level.
ATTENTION
If a screen is mounted over the Compact P, it must be easy to dismantle this.
At the lower rear and sides of the unit, there are punched areas
which can be clipped out, so you do not cuts the holes yourself.
The rear angle iron on the base frame can be removed, allowing the
unit to be pushed closer to the wall, thereby concealing the water
connections.