External heat supply
Compact P is able to control an external room heating such as electric radiators or a floor heating system.
The room temperature is monitored by the Compact P, which block the external heating supply when there is no need for heating. If
Compact P cannot achieve the desired room temperature through the ventilation, the external heating supply is released until the
room temperature is in the desired level.
The external heat supply is connected via relay 8, and set in the touch-display under the menu: Ventilation-/Temperature regulation.
A maximum effect of 500W can be connected (Compact P Polar need to have a transfer relay mounted).