38
Emergency operation central heating
If an error occurs in the controller or components in the GEO heat pump, and the heat pump therefore stops, it will not be able to heat
up the house by the central heating.
If the installer is not able to come right away or the error happens outside the opening hours, and you therefore cannot contact the in-
staller, there is a possibility to heat up the house by setting the heat pump into emergency mode.
The button for emergency operation is located
behind the large door.
The emergency operation has three settings:
I - Auto:
El-supplementation and circulation pump are controlled by the control in
the unit (standard setting)
0 - Off:
El-supplementation is off and cannot by turned on by the control in the
unit
II - Manuel:
El-supplementation and circulation pump is on and cannot be turned off by
the control in the unit.
ATTENTION
In manual operation the supply flow temperature for the central heating can achieve 40 °C.