43
Ecodesign data GEO 6 - Heating pump system for space heating
Model GEO 6
Air-to-water heat pump No
Water-to-water heat pump No
Brine-to-water heat pump Yes
Low-temperature heat pump Yes
Equipped with a supplementary heater Yes
Heat pump combination heater No
Temperature control:
Model CTS602
Class 2
Contribution to seasonal space heating energy efficiency 2%
Item Symbol Value Unit Item Symbol Value Unit
Rated heat output (*) Prated 6,01 kW
Seasonal space heating
energy efficiency
ŋ
s
208 %
*Declared capacity for heating for part load at indoor temper-
ature 20 °C and outdoor temperature of T
j
Declared coefficient of performance or primary energy ratio
for part load at indoor temperature 20 °C and outdoor tem-
perature T
j
T
j
= -7 °C
Pdh
5,29 kW
T
j
= -7 °C
COPd
4,48
T
j
= +2 °C
Pdh
3,32 kW
T
j
= +2 °C
COPd
5,22
T
j
= +7 °C
Pdh
2,09 kW
T
j
= +7 °C
COPd
5,69
T
j
= +12 °C
Pdh
1,30 kW
T
j
= +12 °C
COPd
5,30
T
j
= bivalent temperature
Pdh
6,01 kW
T
j
= bivalent temperature
COPd
4,27
T
j
= operation limit tempera-
ture
Pdh
0 kW
T
j
= operation limit tempera-
ture
COPd
0
For air-water-heating pumps
T
j
= -15 °C (if TOL < -20 °C)
Pdh
kW
For air-water-heating pumps
T
j
= -15 °C (if TOL < -20 °C)
COPd
Bivalent temperature
T
biv
-10 °C
For air-to-water heat pumps:
Operation limit temperature
TOL °C
Cycling interval capacity for
heating
Pcych kW Cycling interval efficiency COPcyc
Degradation co-efficient Cdh 0,99-1
Heating water operating limit
temperature
WTOL
°C
Power consumption in modes other than active mode Supplementary heater
Off mode
P
OFF
0,002 kW Rated heat output Psup 0 kW
Thermostat off-mode
P
TO
0,024 kW
Standby mode
P
SB
0,002 kW Type of energy input
Electri-
cal
Crankcase heater mode
P
CK
0,000 kW
Other items
Capacity control:
Variable compressor
Variable indoor temperature
adjustment
For air-to-water heat pumps:
Rated air flow rate, outdoors
m
3
/h
Fixed indoor water flow
Fixed outdoor water flow
For water-/ brine-water heat
pumps: Rated brine or water
flow rate, outdoor heat
exchanger
1041
m
3
/h
Sound power level, indoors
L
WA
51 dB
Emissions of nitrogen oxides
Q
HE
2386 kWh