127 / 137
05/2008
3
C72
GB
RUS
Dust emissions into the environment -
Indicative values of performance:
normal version - (not suitable for vacuuming hazardous
dusts): retains at least 99.1% of the particles measuring
> = 3 micrometers;
version for dusts hazardous for the health -
(Classes L - M - H):
L, retains at least 99.1% of the particles measuring ≥ 3
micrometers;
M, retains at least 99.9% of the particles measuring ≥
3 micrometers;
H, class H14 Hepa fi lter in accordance with EN 1822.
General recommendations -
ATTENTION DANGER !
Risk of fi re outbreaks and explosions.
The vacuum cleaner can only be used when it is cer-
tain that active sources of ignition are not going to be
vacuumed.
It is forbidden to vacuum the following materials: bur-
ning materials (embers, hot ashes, lighted cigarettes,
etc.), fl ammable liquids, aggressive fuels (e.g. gasoline,
solvents, acids, alkaline solutions, etc.).
It is forbidden to vacuum the following materials: explo-
sive dusts or ones liable to ignite in a spontaneous way
(such as magnesium or aluminium dusts, etc.).
The vacuum cleaner is not suitable for vacuuming
explosive or similar substances, as established by the
laws governing explosive substances, particularly: liquid
fuels and mixtures of fl ammable dusts and liquids.
ATTENTION DANGER !
Emergency
If an emergency situation occurs:
fi lter breakage -
fi re outbreak; -
short-circuit; -
motor block; -
electric shock; -
etc.; -
turn off the vacuum cleaner, unplug it and ask for assi-
stance from specialized personnel.
Note
Check the place of work and substances tolerated for the
vacuum cleaner in version for liquids.
ATTENTION DANGER !
The vacuum cleaners must not be used or stored out-
doors, or in damp places.
Only versions with the level sensor can be used for
liquids.
If not, they can only be used to vacuum dry materials.
ATTENTION DANGER !
Version for liquids.
If foam or liquid spills from the machine, switch off
immediately and check for the cause.
Description of the vacuum cleaner - Labels -
See fi g. 1.
Labels key of fi g. 1 -
Identifi cation plateA-
Code of the Model which includes the Category of use
(L - M - H), Technical Specifi cations, Serial Number, CE
marking, Year of manufacture
Dust containerB-
Fastening latchesC-
HandleD-
InletE-
Inlet plug (only for Class M - H vacuum cleaners)F-
Warning label (only for Class L - M - H vacuum clean-G-
ers)
ExhaustH-
Attention plateI-
Draws the operator’s attention to the fact that the fi lter
must only be shaken when the machine is off (see par.
“Shaking the main fi lter”).
Panel power plateL-
Indicates that the panel is powered by the voltage given
on the data plate.
SocketM-
Socket on the machine, electrical equipment connection
via the dedicated socket located on the control panel.
Switch off the vacuum cleaner before connecting an -
electrical equipment/tool via the socket.
If tools are connected via the machine socket, make -
sure that they are switched off when plugging in.