Technical data
SM_MC_6P Ver.2.0_2021
18
B
Item number: 107146775
MC 6P-120/1950 FA 230-400/3/50 NO
Service manual data
PUMP:
Pressure p
pump
@ Q
nom
bar
115
Pressure p
gun
@ Q
nom
bar
84
Retaining/opening pressure bar
140 +5 / - 0
Flow Q
nom
l/min
30,5
Suction height dry m
1
Suction height primed m
2,5
Pump type -
NA6
Number of pistons -
4
Pump piston type -
Full Ceramic
Cylinder stroke mm
0
Pump oil type -
Castrol Alphasyn T 150
Pump oil amount per pump l
0,95
ELECTRIC:
Electrical data V/ph/Hz
230V/3ph/50Hz
Current @ V
1
A
25
Current limiter A
-
High voltage test voltage V
1500
HV insulation resistance min. MΩ
1
Earth circuit resistance max. Ω
0,2
Speed rpm
1450
Electric diagram item number -
106420552
UNIT DATA:
Nozzle Size -
NT 1500
Max. inlet temperature (suction) °C
50
Max. inlet temperature (primed) °C
70
Max. inlet temperature (pressure fed) °C
80
Max. water inlet pressure bar
10
Min. water inlet pressure bar
1
Max. ambient temperature °C
40
Gun Type -
High Flow Spray Handle
Lance primary/secondary -
101406108/None
High pressure hose -
DN10 x 10m - Black
Sound power typeplate dBA
90
Vibration ISO 5349 Lance 1 m/s
2
<1,5; +/-1
Cleaning Impact kg-force
Fuse size A
C 32
Protection Class -
IPX5
Weight - Machine incl. standard acc. kg
89
Size - Machine alone LxWxH (mm)
775x570x1020
Detergent suction % (+/-) -