18
4.4. Fault & Protections
Fault Code
Fault Details
State
EE
Inlet and outlet water temp.sensor fault
Stop
E01
Wire controller communication protection
Stop
E02
Driver communication protection
Stop
E03
AC current protection
Stop
E04
AC voltage protection
Stop
E05
DC voltage protection
Stop
E06
Phase current protection
Stop
E07
IPM over temp. protection
Stop
E08
DC current protection
Stop
E09
High exhaust temp. protection
Stop
E10
Ambient temp. protection
Stop
E11
High pressure protection
Stop
E12
Low pressure protection
Stop
E14
Low outlet water temp. protectionCooling
Stop
E15
High coil temp.protectionCooling
Stop
E16
High outlet water temp. protectionHeating
Stop
E17
Water flow protection
Stop
E18
High pressure switch protection
Stop
E19
Low pressure switch protection
Stop
E20
Power supply phase sequence error
Stop
E21
Power supply phase A lost fault
Stop
E22
Inlet and outlet temp. difference too high protection
Stop

Related product manuals