EasyManua.ls Logo

Nobles STRIVE RIDER - User Manual

Nobles STRIVE RIDER
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DUAL TECHNOLOGY
RIDER CARPET CLEANER
Hygenic
R
Fully Cleanable Tanks
More than clean, it’s ReadySpace.
R
R
®
1032130
Rev. 02 (03-2009)
*1032130*
®
www.nobles.com
OPERATOR MANUAL
STRIVE RIDER

Table of Contents

Other manuals for Nobles STRIVE RIDER

Questions and Answers

  • J
    Joseph RuizAug 15, 2025
    How to troubleshoot a Nobles Vacuum Cleaner with no power?
    • S
      Shelly GonzalesAug 15, 2025
      If your Nobles Vacuum Cleaner has no power, there are several potential causes: * The key may be turned off. If so, turn the key on. * The batteries might be discharged, requiring you to recharge them. * A battery cable may be loose or disconnected; ensure that all battery cable connections are secure. * The circuit breaker may have tripped, in which case you should reset the 5 A circuit breaker. * The main fuse could be blown. Replace the 100 A main fuse.
  • M
    Melissa HintonAug 18, 2025
    What to do if my Nobles STRIVE RIDER has poor water pickup?
    • L
      Lisa SmithAug 18, 2025
      If your Nobles Vacuum Cleaner isn't picking up water effectively, consider these possible solutions: * Replace worn ReadySpace rollers. * Clean any clogs from the vacuum shoes. * If extraction cleaning, replace missing vacuum shoe springs. * Tighten a loose recovery tank drain hose cap. * Securely connect any loose or disconnected vacuum hoses. * Remove any debris clogging the vacuum hose. * Replace a defective vacuum hose. * Ensure the recovery tank cover is closed. * Replace a worn tank cover gasket.
  • C
    Chelsey PorterAug 21, 2025
    Why does my Nobles STRIVE RIDER Vacuum Cleaner have a short run time?
    • S
      spencermcdanielAug 21, 2025
      If your Nobles Vacuum Cleaner has a short run time, consider the following: * The battery charge might be low, requiring you to charge the batteries. * The batteries may need maintenance. * The charger could be faulty; repair or replace the battery charger.
  • D
    Danielle OsbornAug 25, 2025
    What to do if Nobles Vacuum Cleaner has no solution spray or uneven spray?
    • M
      morrischristinaAug 25, 2025
      If your Nobles Vacuum Cleaner has no solution spray or uneven spray (streaking), here are potential solutions: * The solution system may need priming. * Ensure the scrub head is lowered by pressing the cleaning button. * Check if the solution switch is turned off, and turn it on if necessary. * Refill the solution tank if it's empty. * Clean any clogged spray tips. * Clean the plugged solution tank filter. * Clean the clogged solution line filter. * Flush the plumbing system if the solution line is clogged. * Realign the spray nozzle if it's out of alignment.
  • A
    Anthony GarciaAug 27, 2025
    Why does my Nobles STRIVE RIDER not propel?
    • T
      Theresa SmithAug 27, 2025
      If the Nobles Vacuum Cleaner does not propel, here are a few things to check: * Ensure the operator is seated, as the machine requires this for operation. * Verify that the seat sensor wire harness plug is connected; connect it if it's disconnected.
  • K
    Kristen WalkerAug 30, 2025
    What to do if the scrub head will not lower on my Nobles STRIVE RIDER Vacuum Cleaner?
    • J
      Joseph RodriguezAug 30, 2025
      If the scrub head of your Nobles Vacuum Cleaner won't lower, consider these possibilities: * Ensure that you have pressed the cleaning button to lower the scrub head. * The low voltage interrupter may be activated, requiring you to recharge the batteries. * The recovery tank may be full, requiring you to empty it.
  • N
    Natalie WongSep 2, 2025
    Why don't the brush motors operate on my Nobles STRIVE RIDER?
    • J
      Jeffrey ThomasSep 2, 2025
      If the brush motor(s) on your Nobles Vacuum Cleaner do not operate, it might be due to the low voltage interrupt being activated. In this case, recharge the batteries.
  • B
    Brendan WatsonSep 5, 2025
    What causes the vacuum motors on my Nobles STRIVE RIDER Vacuum Cleaner to not operate?
    • B
      brianwoodSep 5, 2025
      If the vacuum motor(s) on your Nobles Vacuum Cleaner do not operate, the low voltage interrupt may be activated. Recharge the batteries to resolve this.
  • J
    Joseph GomezSep 8, 2025
    Why do the spray nozzles drip on my Nobles STRIVE RIDER Vacuum Cleaner when not in use?
    • K
      Kimberly MasonSep 8, 2025
      If the spray nozzles on your Nobles Vacuum Cleaner drip when not in use, it could be due to: * A clogged spray tip filter/check valve (Restorative Extraction spray tips). Clean or replace the spray tip filter. * A clogged or faulty solution solenoid. Clean or replace the solution solenoid.
  • C
    Curtis BakerSep 12, 2025
    Why is there excessive foam on the floor when using my Nobles STRIVE RIDER Vacuum Cleaner?
    • M
      Michael JonesSep 12, 2025
      If excessive foam or cream appears on the floor during ReadySpace cleaning with your Nobles Vacuum Cleaner: * It may be because cleaning detergents were added to the solution tank. Drain and rinse out the solution tank, then refill it with water only. Do not add cleaning detergents. * It could also be due to the use of an unapproved pre-treatment detergent. Use only approved pre-treatment detergents.

Summary

Nobles Strive Rider Operator Manual

Nobles Operation Guide

Machine Data Entry

Fields for recording machine installation details for future reference.

Nobles Operation Procedures

Safety Precautions

Essential safety guidelines and warnings for operating the machine safely.

Machine Components

Visual identification and listing of major machine parts with corresponding numbers.

Control Panel Components

Detailed view and identification of all controls and indicators on the operator panel.

Nobles Machine Installation Guide

Battery Installation

Procedure for safely installing the machine's batteries.

Nobles Dual Cleaning Technology Explained

Nobles Machine Setup Procedures

Nobles Machine Operation Guide

Operating the Machine

Step-by-step guide to operating the machine for cleaning tasks.

Nobles Machine Operation Safety

Emergency Stopping

Procedure for immediate emergency shutdown of the machine.

Nobles Machine Status Indicators

Nobles Fault Identification Codes

Nobles Maintenance and Accessory Tool Use

Accessory Tool Operation

Information on using optional cleaning tool accessories.

Nobles Tank Maintenance Procedures

Operating Accessory Tools

Step-by-step guide for using the accessory cleaning tools.

Nobles Solution Tank and Battery Charging

Battery Charging Procedures

Instructions for safely charging the machine's batteries.

Nobles Routine Machine Maintenance

Nobles Periodic Machine Maintenance

Nobles Extended Periodic Machine Maintenance

Nobles Motor and Battery Care

Nobles System Priming and Safe Jacking

Nobles Machine Transport and Storage Guidelines

Transporting the Machine Safely

Procedures for loading and securing the machine for transport.

Nobles Troubleshooting Guide

Nobles Troubleshooting Guide Continued

Nobles Machine Technical Specifications

Nobles Machine Physical Dimensions

Nobles Strive Rider Parts Manual

Nobles Parts Ordering Instructions

Nobles General Recommended Maintenance

Nobles Replacement Rollers and Brushes

Nobles Main Frame Components

Nobles Seat Assembly Parts

Nobles Steering System Parts

Nobles Instrument Panel Parts

Nobles Front Drive Wheel Parts

Nobles Brake & Accelerator Pedal Parts (SN 10644406-)

Nobles Brake & Accelerator Pedal Parts (SN 10508137-10644405)

Nobles Brake & Accelerator Pedal Parts (SN 00000000-10508136)

Nobles Recovery Tank Parts

Nobles Vacuum Fan Parts

Nobles Solution Tank Parts

Nobles Tanks Drain Parts

Nobles Steering Control Breakdown

Nobles Front Drive Wheel Gearbox Breakdown

Nobles Pump Breakdown

Nobles Electrical System Diagram

Nobles Wire Harness Section 1

Nobles Wire Harness Section 2

Nobles Wire Harness Section 3 (Serial Range A)

Nobles Wire Harness Section 3 (Serial Range B)

Nobles Wire Harness Section 4

Nobles Wire Harness Section 5

Nobles STRIVE RIDER Specifications

Vacuum System IconVacuum System
vacuum fan airflow66.5 CFM
vacuum system airflow - actual ReadySpace48 CFM
vacuum system airflow - actual Extraction32 CFM
vacuum motor airflow – max70-inch/ 1780 mm
vacuum motor sealed water lift70.5 inches
Scrubbing System IconScrubbing System
brush motor power0.54 hp / 0.40 kW
roller/brush speed270 rpm
down pressure ReadySpace - standard104 lbs
down pressure ReadySpace - heavy152 lbs
down pressure Extraction - standard32 lbs
down pressure Extraction - heavy84 lbs
Solution Delivery System IconSolution Delivery System
solution tank capacity32 gal / 121 L
pump max rated pressure250 psi
working pressure at spray tips ReadySpace30 psi
working pressure at spray tips Extraction52 psi
Recovery System IconRecovery System
recovery tank capacity28 gal / 106 L
Power System IconPower System
battery capacity335 AH (@20hr discharge rate)
maximum continuous run time3.0 hours
Transport Drive System IconTransport Drive System
ReadySpace propel speed - variable150 fpm / 46 mpm
Extraction propel speed – variable75 fpm / 23 mpm
propel speed reverse - variable175 fpm / 53 mpm
propel motor power1.1 hp / 0.85 kW
Productivity IconProductivity
theoretical max coverage - ReadySpace13, 000 ft[2] / hr / 1, 208 m[2] / hr
estimated coverage - ReadySpace10, 000 ft[2] / hr / 929 m[2] / hr
theoretical max coverage - Extraction7, 500 ft[2] / hr / 697 m[2] / hr
estimated coverage - Extraction5, 000 ft[2] / hr / 465 m[2] / hr
Weight and Dimensions IconWeight and Dimensions
length61.5 in / 1560 mm
width31.5 in / 800 mm
height52 in / 1325 mm
net weight with batteries1225 lb / 560 kg

Related product manuals