CONFIDENTIAL 
 15 (29) 
  NPE-4 6310/NPL-1 6310i  Repair Hints 
Customer Care Europe, Middle East & Africa    Version 3.0 Approved 
SCCE Training Group  Date 22.04.2003   
 
© NMP 2003 
 Checked by: 
SCCE Training Group 
Approved by: 
SCCE 
Make the following measurements in burst mode with an oscilloscope in DC mode. 
 
 
 
 
Oscilloscope settings:
 
 
Ampl: 200mV 
Time/Div: 1ms/Div 
AC/DC/GND: DC 
 
 
 
 
 
 
 
 
  If not ok, check 67.71 kHz at C714 (DtoS and Biquad filter). 
 
Order of measurement points at C714 (counted from N600 Hagar side):   pins (3/4)= DtoS I/Q; 
     pins (1/2)= Biquad (CM_F and CP_F I/Q). 
 
 
 DtoS
    Biquad 
 
Oscilloscope settings:
 
 
Ampl: 500mV 
Time/Div: 200µs/Div 
AC/DC/GND: DC 
 
 
 
 
 
 
  If the signal is not ok, check in GSM the RX signal 942.4 MHz at channel 37, RF level –55 dBm at L626. 
  If the signal is not ok, check in PCN the RX signal 1842.4 MHz at channel 700, RF level –55 dBm at L616 
  If both RX signals not ok, check RX lines from N600 Hagar to X802 antenna connector for shorts or 
disconnections. 
 
 
Check the following voltages: 
 
Check VR4 = 2.8 VDC at C601 
Check VR5 = 2.8 VDC at C604 
Check VR6 (VBB) = 2.8 VDC at C605 
Check VR1A (VCP) = 4.7 VDC (supply for control voltage VC for SHF oscillator) at C600 
Check VR7 = 2.8 VDC at C299 (supply voltage VCC for SHF oscillator) 
Check VREF01 and VREF02 = 1.35 VDC at R726 
 
  - If one of the voltages described above is not ok, check UEM D200.