NSM–3/3D
Service Software Instructions
PAMS Technical Documentation
Page 37
Issue 4 02/2002
Nokia Mobile Phones Ltd.
value range is –100%...100%. The value is rounded to the
nearest integer value.
Tune A
mplitude Difference scroll bar (ALT+A):
When this selection is made the user can increase or decrease
the amplitude difference within 0.1 dB steps. The value range
is –1...1.
Tune P
hase Difference scroll bar (ALT+P):
When this selection is made the user can increase or decrease
the phase difference within 0.5° steps. The current phase dif-
ference is shown on the tuning window with numbers and bar
figure. The value range is 85...95.
Save/OK button (ENTER):
Dialog is closed and tuning
is saved
to phone. When tuning
NSM–X phones in GSM band button values are only saved to
PC memory and those values may be used when tuning is
started in PCN band.
Cancel button (ESC):
Dialog is closed and tuning
is not saved
to phone.
After each value change the new value is sent to the phone.
The next automatic selection is made when TX I / Q tuning function is en-
ded:
Operation Mode = RX pulsed
Update RF Information window
NOTE: Tuning needs to be done for GSM900 and GSM1800 bands sepa-
rately.