38
Table 4 Continued
↓↓
TooHigh!
TooHigh!TooHigh!
TooHigh!
↓↓
Retry
RetryRetry
Retry
?
??
?
Explanation Possible Causes Required Action
The boom is positioned
higher than 70 "
a. The automatic valve test
was started with the
boom positioned too high
a. Manually reposition the booms
into the middle of the cylinder
stroke and resume the test with
the YES (AUTO) switch. For
left and right booms that do not
adjust below the level of the
main boom, you must make
sure that the main boom is
below 50 inches before running
the auto valve test (RETUNE
OR INSTALL).
b. Resume the test with the YES
(AUTO) switch.
↓↓
TooLow!
TooLow!TooLow!
TooLow!
↓↓
Retry
RetryRetry
Retry
?
??
?
Explanation Possible Causes Required Action
The boom is positioned
lower than 30 "
a. The automatic valve test
was started with the
boom positioned too low
a. Manually reposition the booms
into the middle of the cylinder
stroke and resume the test with
the YES (AUTO) switch.
b. Resume the test with the YES
(AUTO) switch.
↓↓
Too
TooToo
Too
Many
ManyMany
Many
↓↓
Retry
RetryRetry
Retry
?
??
?
Explanation Possible Causes Required Action
The system has
detected that too many
sensors are connected.
a. Too many sensors have
been connected to the
system.
a. Remove sensors, or setup the
system manually.