General Information and Specification
OPERATING LIMITS - ALL
MODELS
AC Mode: 132 VAC Max., 108
VAC Min.
15.4 VDC Max., 10.5
VDC Min.
DC Mode: 15.4 VDC Max., 11.5
VDC Min.
Gas Mode: 11" W.C.
15.4 VDC Max., 10.5
VDC Min.
MODELS 652, 653, 6052,
6053 RATINGS
1200 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP14 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 200 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
MODELS 662, 663, 6062,
6063, 6162, 6163 RAT-
INGS
1450 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP16 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 300 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
MODELS 682, 683, 6082, 6083, 6182, 6183 RATINGS
1500 Btu/Hr Input
LP Gas Mode:
11" W.C.
LP16 Orifice
12 Volts DC control voltage
AC Mode:
110 Volts AC, 300 Watts
12 Volts DC control voltage
DC Mode (3-Way only):
12 Volts DC
CURRENT DRAWS - 652, 653, 6052, 6053
Automatic Ignition - Less than 500 milliamps or .50 amps
AC Heating Element - 1.5 amps at 110 Volts AC
1.7 amps at 120 Volts AC
DC Heating Element - 9.2 amps at 12 Volts DC
10.7 amps at 14 Volts DC
CURRENT DRAWS - 662, 663, 682, 683, 6062, 6063, 6082,
6083, 6162, 6163, 6182, 6183
Automatic Ignition - Less than 500 milliamps or .50 amps
Interior Light (when equipped) - 300 milliamps (.3 amps)
Humidity Heater - 240 milliamps (.24 amps)
AC Heating Element - 2.7 amps at 110 Volts AC
2.9 amps at 120 Volts AC
DC Heating Element - 13.8 amps at 12 Volts DC
16.1 amps at 14 Volts DC
B101
40