P749
Status of DIP switches
(Status of DIP switches)
0000 ... 01FF (hex)
or
0 ... 511
(dec)
Bit 8: from SW 1.3
This parameter shows the actual setting of the FI DIP switch "S1" (See BU0200)
chapter 4.3.2.2 "DIP switches (S1)").
Bit 0:
Bit 1:
Bit 2:
Bit 3:
Bit 4:
Bit 5:
Bit 6:
Bit 7:
Bit 8:
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
DIP switch 5
DIP switch 6
DIP switch 7
DIP switch 8
EEPROM (memory module) Bit 8 = 0: plugged in / Bit 8 = 1: not plugged in
Pos: 61 7 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 ...) /P700- P799 /Para meter P750 – Sta tistik Übers trom @ 0\mod_1328178425687_388.docx @ 13566 @ @ 1
P750
Stat. overcurrent
(Overcurrent statistics)
S
0 ... 9999 Number of overcurrent messages during the operating period P714.
Pos: 61 8 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P751 – Statis tik Über span nung @ 0\ mod_1328178489671_388.docx @ 13589 @ @ 1
P751
Stat. Overvoltage
(Overvoltage statistics))
S
0 ... 9999 Number of overvoltage messages during the operating period P714.
Pos: 61 9 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 ...) /P7 00-P7 99/Par amet er P752 – Statisti k Netz fehler @ 0\mod_1328178531108_388.docx @ 13612 @ @ 1
P752
Stat. mains failure
(Mains failure statistics)
S
0 ... 9999 Number of mains faults during the operating period P714.
Pos: 62 0 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P753 – Statis ti k Über te mper at ur @ 0\mod_1328178578373_388.docx @ 13635 @ @ 1
P753
Stat. overtemperature
(Overheating statistics)
S
0 ... 9999 Number of overtemperature faults during the operating period P714.
Pos: 62 1 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P754 – Statisti k Para meter verlus t @ 0 \mod_1328178629935_388.docx @ 13658 @ @ 1
P754
Stat. parameter lost
(Parameter loss statistics)
S
0 ... 9999 Number of parameters lost during the operating period P714.