EasyManua.ls Logo

Nord Drivesystems NORDAC FLEX SK 200E Series - Page 220

Nord Drivesystems NORDAC FLEX SK 200E Series
284 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NORDAC FLEX (SK 200E ... SK 235E)Users Manual for Frequency Inverters
220 BU 0200 en-3118
Pos: 62 3 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P755 Statisti k S yst emf eh ler @ 0\mod_1328178677434_388.docx @ 13681 @ @ 1
P755
Stat. system error
(System fault statistics)
S
0 ... 9999 Number of system faults during the operating period P714.
Pos: 62 4 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par amet er/ Par amet erau fli st ung (P 000 .. .)/P 700- P799 /Par amet er P756 S tatisti k Ti me Out @ 0\mod_1328178715996_388.docx @ 13704 @ @ 1
P756
Stat. Timeout
(Time out statistics)
S
0 ... 9999 Number of Time out errors during the operating period P714.
Pos: 62 5 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P757 Statistik Kundenfehler @ 0\mod_1328178758542_388.docx @ 13727 @ @ 1
P757
Stat. Customer error
(Customer fault statistics)
S
0 ... 9999 Number of Customer Watchdog faults during the operating period P714.
Pos: 62 6 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P760 Aktueller Strom [SK 1x0E, SK 2xxE] @ 2\mod_1346932211538_388.docx @ 43728 @ @ 1
P760
Actual mains current
(Actual mains current)
S
0.0 ... 999.9 A Displays the actual input current.
Pos: 62 7 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Par ameter aufli stung (P000 .. .)/P7 00-P7 99/Par amet er P799 Betrie bss tun den l etz te Stör ung 1.. .5 @ 0\mod_1328178802042_388.docx @ 13750 @ @ 1
P799 [-01]
...
[-05]
Op.-time last error
(Operating time, last fault 1...5)
0.1 ... ___ h This parameter shows the operating hours counter status (P714) at the moment of the previous
fault. Array 01…05 corresponds to the lastest fault 1…5.
Pos: 62 9 /Anlei tung en/El ektr onik/FU und Star ter/6 . Meld ungen zum Betr iebsz usta nd/_M eldung en zu m Betrieb szustand_01 (Überschrift + Inhalt) [SK xxxE] @ 3\mod_1361795506047_388.docx @ 59670 @ 1555 @ 1

Table of Contents

Other manuals for Nord Drivesystems NORDAC FLEX SK 200E Series

Related product manuals