5.2 Description of parameters
Pos: 23 7 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Allg emei n/Par ameter beschr eib ung_0 2 [SK 1x5 E, SK 1xx E-FDS, P OSIC ON, S afety ] - ne ue Dars tellu ngsvar iant e @ 9\mod_1446537266668_388.docx @ 260250 @ @ 1
P000 (parameter number) Operating display (parameter name) xx
1)
S P
Setting range
(or display range)
Display of typical display format (e.g. (bin =
binary) of possible setting range and number
of decimal places
Other applicable
parameters:
List of other directly related
parameters
Arrays
[-01]
If parameters have a substructure in several arrays, this is shown here.
Factory setting
{ 0 }
Typical default setting of parameters in the as-delivered condition of the FI, or to which it is set after
carrying out "Restore factory settings" (see parameter P523).
Scope of Application
List of variants for which this parameter applies. If the parameter is generally valid, i.e. for the entire model
series, this line is omitted.
Description
Description, function, meaning and similar for this parameter.
Note
Additional notes about this parameter
Setting values
(or display values)
List of possible settings with description of their respective functions
1)
xx = Other codes
Figure 1: Explanation of parameter description
Information
Unused lines of information are not listed.
Pos: 23 8 /Allg em ein/ Allg em eingül tig e M od ule/ ---------Seiten umbr uc h kom pakt --------- @ 13\mod_1476369695906_0.docx @ 2265495 @ @ 1
Pos: 23 9 /Anlei tung en/El ektr onik/FU und Star ter/5 . Par ameter/ Allg emei n/Par ameter beschr eib ung_0 3 [POSI CON, S afety , SK 5xxP] @ 14\mod_1479133032600_388.docx @ 2304028 @ @ 1
Notes / Explanations
Code Designation Meaning
S
Supervisor parameter
The parameter can only be displayed and changed if the
relevant supervisor code has been set (see parameter
P003).
P
Depending on the
parameter set
The parameter provides various setting options which
depend on the selected parameter set.

Table of Contents