3.3 Internal Customer Unit
BU 0200 GB Subject to technical alterations 67
DIP switches for selection of 0-10V, 0-20mA, 4-20mA and system bus
DIP Switches, SK CU4-IOE
1
2
CAN-AD0
CAN-AD1
00 CAN Address 20
System bus
01 CAN Address 21
10 CAN Address 22
11 CAN Address 23
3 CAN-BR
off CAN Normal operation
on CAN Broadcast
4
5
6
AIN 1
000 0 ... 10V
001 2 ... 10V
010 -10V ... +10V
011 not permissible
100 0 ... 20mA
101 4 ... 20mA
110 not permissible
111 not permissible
7
8
9
AIN 2
000 0 ... 10V
001 2 ... 10V
010 -10V ... +10V
011 not permissible
100 0 ... 20mA
101 4 ... 20mA
110 not permissible
111 not permissible
10
11
AOUT
00 0 ... 10V
01 2 ... 10V
10 0 ... 20mA
11 4 ... 20mA
12
AOUT
inverted
off 100% Setpoint = 10V
on 100% Setpoint = 0V
Status LEDs
Module fault
green
red
Error / Error number / System bus. For further details please refer to the BUS Manual.