4.1.2 Potentiometers P1 and P2 and diagnostic LEDs
The enable signal (Start/Stop) is implemented with the external switch. The setpoint value can be fixed with
the integrated potentiometer P1. The potentiometer P2 is available for selection of the start-up and braking
ramps.
SK200E,topview
RJ12
RS232
RS485
P1/P2
LEDFI
LEDASi
Diagnostic
LEDs
Diagnostic LEDs (4.1.2.1) Potentiometer and LEDs (4.1.2.2)
P1 (continuous) P2 (stepped)
1 yellow Digital output 0% P102/103 P105 - - -
2 yellow Digital input 1 10% 0.2s 10Hz 1 P102/103 P104
3 yellow Digital input 2 20% 0.3s 20Hz 2 0.2s 2Hz
4 yellow Digital input 3 30% 0.5s 30Hz 3 0.3s 5Hz
5 yellow Digital input 4 40% 0.7s 40Hz 4 0.5s 10Hz
6 yellow Motor PTC 50% 1.0s 50Hz 5 0.7s 15Hz
7 yellow Brake chopper active 60% 2.0s 60Hz 6 1.0s 20Hz
8 yellow Mech. brake status 70% 3.0s 70Hz 7 2.0s 25Hz
9 green Bus Status 1 80% 5.0s 80Hz 8 3.0s 30Hz
10 red Bus Status 2 90% 7.0s 90Hz 9 5.0s 35Hz
100% 10.0s 100Hz 10 7.0s 40Hz
The function of P1 and P2 depends on DIP 4/5 (Section 4.1.1).
The function changes according to the setting.
As standard, P1 sets the setpoint value of 0-100% and P2 sets the
ramp from 0.2-7sec.
LED FI
green
red
Ready / Load (flashing)
Error / Error number (flashing)
LED AS-I
green
red
AS-Interface status (dual LED)