NORDAC SK 200E Manual
76 Subject to technical alterations BU 0200 GB
3.5.1.4 Installing the SK TI4-TU-... on the SK 200E
The installation of the Technology Units on the
SK 200E is performed as follows:
1. Switch off the mains.
2. Remove the two M25 protective caps.
3. Glue a suitable seal to the SK T14-TU
Connection Unit.
4. Install the SK T14-TU-… with seal on the SK
200E and carry out the electrical connections.
5. Fit and screw on the SK TU4 module.
3.5.1.5 Wall mounting of the SK T14-TU-…
The connecting cable between the Technology Unit and
the SK 200E should not be longer than 30m.
1. Use the SK TIE4-WMK-TU wall mounting kit for the
SK T14-TU-... to install the Technology Unit at a
distance from the SK 200E.
2. Glue a suitable seal to the SK T14-TU Connection
Unit.
3. Make a suitable connection between the Technology
Unit and the frequency inverter. Take care that there
is appropriate screw fitting and sealing of the
modules.
4. Fit and screw on the SK TU4 module.
SKTIE4‐WMK‐TU e.g.SKTI4‐TU‐NET e.g.SKTU4‐POT
136mm
58mm