Version 3/01 Page 12/25
Reading alarm and warning data:
Enter crusher control display (Press F1 in main menu).
Select ALARMS (Press F4).
Function keys in alarm mode are as follows:
Key Function Description of function
F1 Select Selects event.
F3 Acknowledge all Acknowledges all events.
F5 Move up Moves cursor upwards on the list.
F6 Move down Moves cursor downwards on the list.
F7 Close Exit to crusher control display.
In the alarm screen you can examine single events by pressing F1. This screen presents
more information, such as setting, pressure, power, etc.
An alarm will be sent if a limit value is exceeded or not reached. An alarm will stop the
device, if necessary. An alarm is often related to the actions of the operator. If a safety
device is triggered, an alarm will follow.
Following additional information is gathered on alarms and warnings:
Code and point of sending
Measured values; setting, pressure, and power at the time of alarm
Operating hours at the time of alarm
Number of alarms/warnings of this type within operating hours
Time of first alarm/warning of this type
Acknowledgement of message; acknowledged events with prefix @
Lubrication pressure : OK/not OK
Oil filter: OK/not OK
Oil temperature: low/OK/high
Oil flow: on/off
Oil level: on/off
Cooler status: on/off
Heater status: on/off