The crusher is started and stopped through the start/stop menu. By selecting F2 in the
main menu you enter the diagnostics display, and from there by pressing F3 to start/stop
menu. The crusher and its auxiliary devices can be started one by one or in the sequence.
When starting in a sequence, the crusher's controller automatically starts the lubrication,
the crusher, and the feeding device in steps while controlling starting conditions for each
device.
3.4.1 Starting lubrication
Enter diagnostics display (Press F2 in main menu).
Select start/stop (Press F3).
Highlight lubrication in the start-stop-sequences menu (F5 up, F6 down).
Start lubrication (Press F1).
Only the lubrication will start now. During the start, the red OFF on the lubrication line
turns yellow, and then into green ON.
Press F7 to exit.
Starting conditions for lubrication
All the safety devices must be OK.
Oil temperature in the tank has to be warm enough. The starting temperature is set in
system parameters.
After lubrication has started, the lubrication pressure has to increase during 10
seconds.
30 seconds after the lubrication is started, the lubrication oil flow has to be ok.
If the controller can not recognize the oil pressure or flow, controller will stop the
lubrication and give an error message. The delay for recognition is set in system
parameters