Version 3/01 Page 17/25
The crusher is started and stopped through the start/stop menu. By selecting F2 in the
main menu you enter the diagnostics display, and from there by pressing F3 to start/stop
menu. The crusher and its auxiliary devices can be started one by one or in the sequence.
When starting in a sequence, the crusher's controller automatically starts the lubrication,
the crusher, and the feeding device in steps while controlling starting conditions for each
device.
3.4.1 Starting lubrication
•
Enter diagnostics display (Press F2 in main menu).
•
Select start/stop (Press F3).
•
Highlight lubrication in the start-stop-sequences menu (F5 up, F6 down).
•
Start lubrication (Press F1).
Only the lubrication will start now. During the start, the red OFF on the lubrication line
turns yellow, and then into green ON.
•
Press F7 to exit.
Starting conditions for lubrication
•
All the safety devices must be OK.
•
Oil temperature in the tank has to be warm enough. The starting temperature is set in
system parameters.
•
After lubrication has started, the lubrication pressure has to increase during 10
seconds.
•
30 seconds after the lubrication is started, the lubrication oil flow has to be ok.
•
If the controller can not recognize the oil pressure or flow, controller will stop the
lubrication and give an error message. The delay for recognition is set in system
parameters