Version 3/01 Page 22/25
Lubrication oil temperature sensor message is over working limit. Check the sensor
and cable. Replace if necessary.
Return oil sensor ok.
There was a fault in lubrication oil temperature sensor. Now the sensor has recovered.
5.1.5 Power
Power limit exceeded!
You have reached the crusher's power limit. Decrease loading (increase setting or
decrease feed).
Fault in crusher power detector
The output of the device measuring crusher power is below allowed area. Check the
device and replace it if necessary.
Fault in crusher power detector
The output of the device measuring crusher power is above the allowed area. Check
the device and replace it if necessary.
Power measuring ok
There was a fault in power measurement device, but now the device is ok.
5.2 Safety Devices
Error/information messages related to safety devices:
Feeding device safety device OK.
Feeding is allowed.
Feeding device safety device tripped.
Feeding is disabled.
Lubr. oil cooler safety device OK.
Feeding is allowed.
Lubr oil cooler safety device tripped.
Feeding is disabled.
Lubrication pump safety device OK.
Activating the lubrication pump is allowed.
Lubrication pump safety device tripped.
Activating the lubrication pump is disabled.