Version 3/01 Page 15/25
3.2 Trends
Reading trends
•
Enter main menu.
•
Choose Diagn. (press F2).
•
Choose trends (press F1)
•
Press F7 to exit.
The table below describes the functions of the trend screen:
Key Function Description of function
F1 Tank temperature Oil temperature in the tank [_C /_F].
F2 Return temperature Crusher lubrication return oil temperature [_C / _F].
F4 Load profile This trend is created from values of pressure and power. The
current value of pressure is compared to its maximum value,
and current power value to maximum power value. Higher of
these values is saved to the trend.
For example:
measure actual value max value %
pressure 10 bar 20 bar 50
power 75 kW 250 kW 30
! 50% is saved to the trend.
vibration 75% 100% 75
power 150 kW 250 kW 60
! 75% is saved.
F5 Timescale
24 h <--
Changes the time scale shown on the screen. The time
alternatives are 24 hours, 6 hours, 60 minutes (1 h), and 6
minutes.